OHMSPA Functions
Similarities and Differences of Special Permits and Approvals
Current and Frequently Requested Special Permits
Required Information for Requesting a Special Permit
Required Information for Requesting an Approval

UN Third Party Certification Agencies (pdf 39KB)
The agencies listed within this document are certified to perform UN Certified 3rd party testing of non-bulk performance oriented packagings.

[Get Acrobat Reader]

 

Procedures for Application for Approval to Requalify DOT Cylinders


  • The cylinder retester must contact one of the approved Independent Inspection Agencies to arrange for an inspection of his facility.


  • After the inspection, the Independent Inspection Agency must complete a report and forward the report to the cylinder retesters.


  • It is the responsibility of the applicant to submit: (1) a complete application (can be in any format as long as it contains all of the required information set forth in Section 107.805; and, (2) the Independent Inspector's report.

The applicant should have at the time of inspection:

  • A copy of Title 49, Code of Federal Regulations, Parts 100-199 or reprint. Copies of this document may be obtained from:
  • Superintendent of Documents
    U.S. Government Printing Office
    Washington, D.C. 20402
    (202) 783-3238

    Click here for information about obtaining 49 CFR.

  • Where applicable, a copy of a current special permit document authorizing the use of a non-DOT specification cylinder. Current copies of special permit documents may be obtained from:
  • U.S. Department of Transportation
    Office of Hazardous Materials Special Permits and Approvals
    Records Center PHH-30
    1200 New Jersey Avenue, SE East Building, 2nd Floor
    Washington, DC 20590
    Phone: (202) 366-5046    FAX: (202) 366-3753

    Click here to access electronic copies of special permits.

  • Compressed Gas Association Pamphlets C-1, C-6, C-6.1, C-6.2, C-8, obtainable from:
  • Compressed Gas Association
    4221 Walney Road, 5th Floor
    Chantilly, VA 20151-2923
    Phone: 703-788-2700

    Click here to access the Compress Gas Association website Exiting PHMSA
.

  • A certification of calibration for the test guage through its operating range.
  • A calibration cylinder and a chart showing the cylnder's expansions at various test pressures.
  • Note: Due to inconsistancies in the repeatability of calibration, the use of a fiber reinforced plastic (FRP) full composite cylinder as a calibration cylinder is discouraged.
  • Hydrostatic test equipment capable of producing an accuracy of 1 percent.
  • Equipment necessary for performing required visual inspections.
  • A sample of the facility recordkeeping form.

NOTE: A .pdf file allows you to view/print the document in its original format. In order to view it, you must have Adobe Reader properly configured with your browser. You may download this software FREE from Adobe's Web site. For best viewing results, change Adobe Reader's view setting to "Fit Visible". Get Adobe Acrobat Exiting PHMSA